Console House 10 Mode Instruções de Operação

Consulte online ou descarregue Instruções de Operação para Sistemas de segurança - controlo de acesso Console House 10 Mode. Console House 10 Mode Operating instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 136
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
INTRODUCTION
Thank you for purchasing your new Omni automation system. You
are about to enjoy a new feeling of security, peace of mind, and
convenience.
We at Home Automation, Inc. hope that you will take a few moments
to become familiar with all of the features of this fine product by
reviewing this manual. Please keep this manual on file for future
reference.
It is recommended that you also review the installation and operating
instructions provided with your smoke and gas detectors (if used in
your system). If you do not have a copy of these documents, ask your
installer -
See
Underwriter's Laboratories Requirements.
In the event that there are any questions, please call your installer first.
If you need assistance directly from the manufacturer, please call us at
(504) 833-7256, between the hours of 9:00 AM and 5:00 PM, Central
time. We will be happy to assist you.
When calling, please have the model and serial number of the unit that
you have, which can be found on the inside of the controller.
For your convenience, we suggest that you record this information:
MODEL NUMBER: ________________________
SERIAL NUMBER: ________________________
The 10A00-1 and -4 Omni controllers and consoles have been tested
and Listed by UL for the following applications:
UL 985 - Household Fire Warning System Units
UL 1023 - Household Burglar Alarm System Units (Grade A)
Underwriter's
Laboratories
(UL) Listing
Home Automation, Inc. 1
Vista de página 0
1 2 3 4 5 6 ... 135 136

Resumo do Conteúdo

Página 1 - INTRODUCTION

INTRODUCTIONThank you for purchasing your new Omni automation system. You are about to enjoy a new feeling of security, peace of mind, andconvenience

Página 2

- In the event that the alarm has been activated, the menu keys and the arrow keys are locked out. You must silence the alarm using the OFF, DAY, NIGH

Página 3 - OVERALL DESCRIPTION

1, 2, 3, 4, 5, 6, 7, or 8, respectively. When you have entered the dialorder of your choice, press ' # '. Enter a single ' 0 ' if

Página 4

Some doors (a back door or garage door) may be configured as adouble or quadruple entry delay. If so, that door has two times or fourtimes the entry

Página 5 - Normal Top-Level

When Entry/Exit Chime is set to Yes, the console(s) will beep oncewhen a door on an entry/exit zone is opened, even if the alarm systemis off. This l

Página 6 - Display Menus

display "ZONE NOT RDY". If the system is armed and a zone is openwhen the Exit Delay expires, the alarm will sound.This option will instruc

Página 7

If your system is set up with High Security On, the display will requestthe Master or Manager code whenever you select one of thesefunctions, even if

Página 8

The default Flash For Alarm is Unit 2. You may enter one number forthe unit number you wish to have flash, or ' 0 ' for none.To change the

Página 9 - SECURITY SYSTEM OPERATION

The default setting for HC 2 X-10 All Off is On.This feature allows you to choose if House Code 2 will respond to theX-10 All On commands.HC 2 X-10 AL

Página 10 - Security System

Time Clocks 2 and 3 is entered into the system and set for time anddates exactly like Time Clock 1.The system automatically calculates the time of sun

Página 11 - (NIGHT DELAY)

It is not necessary to alter the time zone to compensate for daylightsavings time, the Omni will automatically adjust its calculations forsunrise and

Página 12 - Quick Arm

To enter a name, enter the two digit code shown in Table 2 in theAppendix for each character in the name, then press the ' # ' key. Usethe

Página 13 - Bypassing Zones

3 = AWAYUse the AWAY mode when you leave and no one is there. All doors,windows, and motion detectors are armed. All zones have an ExitDelay so that

Página 14 - Restoring Zones

To enter a voice description, enter the one, two, or three digit codeshown in Table 2 in the Appendix C for each description (word orgroup of words),

Página 15 - Come Home

"THE JONES RESIDENCE, 1234 JOHNSON STREET, CORNER OFJOHNSON AND THIRD STREET"The unit will beep after 8 seconds, then play the address back

Página 16 - When the Alarm

SAMPLE PROGRAMSTo create a program, enter the Set Up Program menu as follows:PRESS ONKEYPADEXPLANATION OF ACTION 8, CODE, 3, 1 SETUP, ENTER SECURITY C

Página 17

SECURITY OFF AT 6:00 AM MTWTF-- (MONDAY-FRIDAY) &IF NIGHT PRESS ONKEYPADEXPLANATION OF ACTION1, 1, 1, 6 0 0 ↑WHEN, TIMED, TIME, 6:00 AM2, ↓, 8, #

Página 18 - Emergency Keys

ENERGY SAVER COOL SETPOINT TO 76 AT 5:00 PM MTWTF-- &IF AWAY PRESS ONKEYPADEXPLANATION OF ACTION1, 1, 1, 5 0 0 ↓WHEN, TIMED, TIME, 5:00 PM2, ↓, 8,

Página 19

Button ProgramsFOYER LIGHT ON FOR 5 MINUTES WHEN FRONT DOOR NOT RDY &IF DARK PRESS ONKEYPADEXPLANATION OF ACTION1, 2, #, 3, 1 #, 1 WHEN, BUTTON, M

Página 20

ENERGY SAVER COOL SETPOINT TO 84 WHEN SECURITY AWAYPRESS ONKEYPADEXPLANATION OF ACTION1, 2, #, 2, 3, # WHEN, BUTTON, MENU, SECURITY AWAY, ENTER2, 5, 1

Página 21

UNDERWRITER'S LABORATORIESREQUIREMENTSFor a complete list of requirements and restrictions when installing theOmni panel in a UL Listed system, r

Página 22 - Indications

Your fire protection system is designed to provide warning in theevent of a fire. It is your responsibility to plan your escape routes inthe event of

Página 23

FEDERAL COMMUNICATIONCOMMISSION (FCC) NOTICE:1.This equipment complies with Part 68 of FCC Rules. On the door, inside of the Omni enclosure, is a lab

Página 24 - Area Arming

The console will beep once and the console LED will be set to red.The top line will display the security mode. The bottom line willdisplay, " **

Página 25

Service can be obtained at:HOME AUTOMATION, INC.2709 RIDGELAKE DRIVEMETAIRIE, LA. 700027.This equipment may not be used on coin service provided by th

Página 26 - GOTO Area

CANADIAN INDUSTRY CANADA NOTICEThe Canadian Industry Canada label identifies certified equipment.This certification means that the equipment meets cer

Página 27 - Testing Your

requirement that the total of the Load Numbers of all the devices doesnot exceed 100.This digital apparatus does not exceed the Class B limits for rad

Página 28 - Maintenance

DIAL OUT PLANNERUse the following dial-out planner to help you set-up the voice dial-out numbers:Omni Voice Dial-Out PlannerDIAL OUT NUMBER 1: ______

Página 29

DIAL OUT NUMBER 6: __________________________________ AREA: _____________DIAL OUT 6 ON: TIME: _______________ DAYS: _______________DIAL OUT 6 OF

Página 30

INSTRUCTIONS TO CALLED PARTYDear ___________________________________________________________________I have programmed my Omni Home Automation system t

Página 31 - Powerhouse™

OMNI DEFAULT SETTINGSUse this list to make a record of the settings in your system. Shown are the factory settings.Set-Up Dial TELEPHONE ACCESS: 0=OF

Página 32

DIAL OUT NUMBER 4: -DIAL OUT 4 ON: 12:00AM MTWTFSSDIAL OUT 4 OFF: NEVERDIAL OUT NUMBER 5: -DIAL OUT 5 ON: 12:00AM MTWTFSSDIAL OUT

Página 33 - Controlling Units

Set-Up ArmingENTRY DELAY: 15-45 SECONDS 15EXIT DELAY: 15-180 SECONDS 15AUDIBLE EXIT DELAY: 0=NO, 1=YES 1ENTRY/EXIT CHIME: 0=NO, 1=YES 0PERIMETER C

Página 34

TIME CLOCK 1 OFF TIME: NEVERTIME CLOCK 2 ON TIME: 12:00 AM MTWTFSSTIME CLOCK 2 OFF TIME: NEVERTI

Página 35 - Timed Commands

8 = BYPASSYou can Bypass a zone that you do not want protected while thesystem is armed. Bypassing is also the only way that a tamper or panic zone ca

Página 36

OMNI SPECIFICATIONSSize: Controller: 13W x 13H x 4.5DConsole: 4.6W x 4.5H x 1.2DWeight: Controller: approx. 10 lb.Console: approx. 0.5 lb.Operating

Página 37 - All On / Off

Controller Maximum Group Current Outputs:Devices: AUX 12 VDC, SWITCH 12 VDC,CONSOLE, and OUTPUTS 1 - 8: 1 AHorn: INT HORN and EXT HORN: 1 AControlle

Página 38

TABLE 1 - CHARACTER CODESCODE CHAR CODE CHAR CODE CHAR CODE CHAR000102030405060708091011121314151617181920212223SPACE!"#$%&'()*+,-./0123

Página 39 - Thermostats

TABLE 2 - VOICE DESCRIPTIONSCODE DESCRIPTION CODE DESCRIPTION 1 2 3 4 5 6 7 8 9101112131415161718192021222324ELEVENTWELVETHIRTEENFOURTEENFIFTEENSIXTEE

Página 40

CODE DESCRIPTION CODE DESCRIPTION4950515253545556575859606162636465666768697071727374BUILDINGBURGLARBUTTONBYPASSCANCELCENTERCLOSETCODECONTINUE(BEEP)CO

Página 41

CODE DESCRIPTION CODE DESCRIPTION101102103104105106107108109110111112113114115116117118119120121122123124125126HUNDREDINSTANTINTERIORINVALIDISKITCHENL

Página 42

CODE DESCRIPTION CODE DESCRIPTION153154155156157158159160161162163164165166167168169170171172173174175176177RIGHTRISEROOMSAVERSECONDSSECURESECURITYSET

Página 43

Note that there is an exit delay before the system is armed in anymode. The bypass will only take place if the zone is not ready whenthe exit delay i

Página 44 - Modules (PESMs)

The console will beep and the display will return to the top-leveldisplay. To Bypass or Restore a zone in another area, you must first"go to"

Página 45

BURGLAR ALARM ACTIVATEDIf someone enters through any zone other than an Entry-Exit zone, ifthe security system is in the Night mode, or if the securit

Página 46 - ↓

If you are using both central station monitoring and voice dial out,then the voice dial out is delayed by five minutes to give the centralstation tim

Página 47

When the gas alarm is activated, the alarm responds exactly asdescribed under Burglar Alarm Activated, except:- The console display reads,"GAS AL

Página 48

When the 1 key and the 3 key is pressed simultaneously, the PoliceEmergency alarm is activated. This alarm operates exactly the sameas described for

Página 49 - 1 = CTRL (CONTROL UNITS)

The 10A00-4 Omni controller has also been tested and Listed by ULfor the following applications:UL 365 - Police Station Connected Burglar Alarm Units

Página 50 - 2 = ZONE

The Fire Emergency alarm can be turned off at any time by pressingthe ' * ' key.When the 7 key and the 9 key is pressed simultaneously, the

Página 51

(See Duress Code for a description of when to use.)In the event that you enter your duress code, or a zone configured as aDuress zone is tripped, the

Página 52 - 5 = TEMP (TEMPERATURE)

The Omni constantly monitors the alarm zones and several internalmatters and will alert you if it detects trouble. The particular trouble isindicated

Página 53 - Event Log

This indication will remain until the digital communicator tries again (as a result of a reportable alarm or event occurring) or until both phone numb

Página 54

User code 1 is always set to a Master code - See Set Up Codes.The Manager codes can arm/disarm the security system in assignedareas, during assigned t

Página 55

If you have a Master code, your code is valid in any area. If you are inArea 2, and wanted to arm the system in the Away mode, simply pressthe AWAY k

Página 56 - TELEPHONE CONTROL

As the four-digit code is entered, "X" characters are echoed after the"ENTER CODE:" prompt.If the Master code or a valid code is e

Página 57

assigned to that area (AREA 2). All status displays will show thestatus of the selected area.The top line of the display will show the name and secur

Página 58 - Remote Lockout

7. Press the ' * ' twice to return to the top-level display. Have a partner open each door and window, then close it. The display should s

Página 59 - Alternate Method

For smoke detectors, motion detectors, and other components notmanufactured by Home Automation, Inc., follow maintenanceprocedures outlined by the man

Página 60 - Main Menu

OVERALL DESCRIPTIONThe console is designed with everything that is necessary for you toprogram and operate your Omni control and security system. Bec

Página 61 - 1 - Control

CONTROLThe control features of the Omni make it easy and convenient tocontrol almost any light or appliance from the console or over thetelephone. Yo

Página 62

The Omni controls lights and appliances by sending commands overyour existing electrical wiring to special switches, outlets, receptacles,and modules,

Página 63 - 2 - Security

When placing items under remote or automated control, always givedue consideration to the safety aspects of turning an appliance on oroff without bein

Página 64

The control menu is used when controlling lights and appliances. Toenter the control menu, from the top-level display or from the mainmenu, press the

Página 65

The console display top line will read "UNIT NAME" (unit namebeing the description of the unit number), and the bottom line willread "S

Página 66 - 5 - Temperature

Press the 4 key to set the desired lighting level of the specified unit.Enter a number (0-100) to indicate the lighting level (intensity) of theunit.L

Página 67

Porch Lights For 2H0=OFF 1=ON 2=DIM 3=BRT↓At this point, you can choose to: - Turn the unit (Porch Light) OFF {FOR 2 HOURS}- Turn the unit (Po

Página 68

To see the last command sent to a unit number by the Omni controller,from the control menu, press the ' # ' key. The last command alongwith

Página 69

A powerful feature of the Omni is the ability to program Buttons. AButton (also known as macro) is a number on the keypad that is pro-grammed to run

Página 70 - (# # # # # #)

Your Omni can control temperatures of your heating and coolingsystem, monitor the outside temperature, and detect high and lowtemperatures in special

Página 71 - Digital Dialer

move about freely inside. In this mode, there is an entry delay onentry-exit zones.3- ' NIGHT 'The ' NIGHT ' key is used to arm t

Página 72 - Voice Dialer

You will be prompted with the first named temperature zone(i.e. Upstairs). The temperature zone can be specified by entering thetemperature zone numb

Página 73

For HAI setpoint only thermostats (no Mode or Fan controls):Upstairs2=TEMP 5=HOLD #=STATTo change the system mode on a thermostat, press 1 (MODE).

Página 74

Upstairs TEMP ENTER TEMPERATURE:Upstairs LOW SETPTENTER TEMPERATURE:(PESM - type temp sensors only)Upstairs HIGH SETPTENTER TEMPERATURE:(PESM - type t

Página 75

Upstairs MODE: AUTO FAN: AUTO ↑If hold mode is On, "HOLD" is shown:Upstairs HOLD MODE: AUTO FAN: AUTO ↑For a heat or cool th

Página 76 - Set Up Codes

The Model 1101 PESM is used when you are have any thermostat,other than a HAI Communicating Thermostat, and would like tocontrol your heating and cool

Página 77

setback temperature 65 degrees and the Cool setback temperature 80degrees when the alarm system is put in the AWAY mode. Anotherprogram can turn the e

Página 78 - Set Up Time

3=COOL 4=TIME #=STAT ↑For temperature sensors:Upstairs2=LOW 3=HIGH #=STAT To set a temperature setpoint, press 2 (HEAT) or 3 (COOL).For Celsius t

Página 79 - Set Up Programs

For an energy saver module, the status shows the current temperature,the heating and cooling setpoints, the energy saver on/off status, andthe time re

Página 80

When the alarm is initiated, the console beeper will be turned on andan alarm dial-out sequence will be initiated after the normal dial-outdelay. Bot

Página 81

outside sirens are not activated) and the central station and/or voicedialer is called. The High and Low setpoints are changed as described for the PE

Página 82

and to give useful information that will guide you through normaloperations of your Omni control and security system.9- Console KeypadThe Console Keyp

Página 83 - Program menu

At this point, you may press the ' # ' key to control the unit as specifiedunder Controlling Units.2 = ZONEThe Zone Status menu allows you t

Página 84 - Edit Programs

The phone status consists of two parts, separated by a "/". The firstpart shows the current phone line state:ONHK - ON HOOK OFFHK - OFF

Página 85 - 1=BEFORE 2=AFTER #=AT

This feature can be used to monitor the quality of the zone wiring andcontacts. If the numbers begin to deviate from their original valueswhen the sy

Página 86

The Event Log records the 100 most recent significant security systemEvents (happenings), and trouble conditions in the system. When anew event occur

Página 87

For security zone bypasses and restores, the event log shows the zonename, whether the zone was bypassed or restored, and the codenumber used:9:00 AM

Página 88

response to an alarm and the called party enters a code. The event logdisplays the code used to access the system and "REM ACCESS":12:05 PM

Página 89

TELEPHONE CONTROLYour Omni is equipped with a built-in telephone response feature thatallows you to control and access the status of your system from

Página 90

again until the next time you pick up your phone. If the Omni hearsany key other than the # key while it is listening in, it disconnectsitself immedi

Página 91 - Edit Program

indicating that an alarm has occurred. Once the Omni has begun todial out, you must use the console to turn off the alarm.You may call your system fro

Página 92

The one-hour lockout does not apply to in-house phones. The lockoutis cleared immediately if the Omni is accessed using an in-housephone.If you have

Página 93 - Condition

If the zone name has not been entered during set up, the display willgive the zone number and zone type. This display will remain for 2seconds, then

Página 94

Once you have successfully logged into your Omni, it will read you amenu of commands, as follows:"WELCOME TO OMNI [AREA 1] PLEASE CHOOSE:1:CONTR

Página 95 - Set Up Dial

To cancel an operation, press ' * ' for Cancel. You will hear"CANCEL" and one beep for a cancel operation.If you make a mistake,

Página 96

press. The Omni will beep once, indicating that it has done what youasked, then go back to the MAIN MENU.For example, 1.The Omni will say, "ON.&

Página 97

Press 2 from the MAIN menu to get to the SECURITY menu.The Omni will say, "SECURITY, PLEASE CHOOSE:"0:OFF1:DAY2:NIGHT3:AWAY4:VACATION5:DAY-I

Página 98

The Omni will say, "[AREA 2]: SECURITY MODE IS OFF."The code must be valid for all areas selected.If Invalid:"INVALID CODE - SECURI

Página 99

If the ' # ' key is pressed, the Omni will read the next three zones andvoice descriptions (if programmed).Select to zone(s) to bypass or re

Página 100 - Set Up Arming

Press 5 from the MAIN menu to get to the TEMPERATURE menu.The Omni will say, "TEMPERATURE: ENTER TEMPERATURE NUMBER, THEN POUND."After a

Página 101

- If the 1 (MODE) key is selected, the Omni will say:"MODE - PLEASE CHOOSE:0: OFF1: HEAT2: COOL3: AUTO- If the 2 (HEAT SETTING) or 3 (COOL SETTIN

Página 102

When an Energy Saver is entered:"ZONE 9 ENERGY SAVER - ENERGY SAVER IS (ON/OFF). TEMPERATURE IS (TEMP).""PLEASE CHOOSE:0: OFF1: ON2:

Página 103 - Miscellaneous

Press 6 from the MAIN menu to get to the STATUS menu."[AREA 1] SECURITY MODE IS (AWAY), (SYSTEM OK), or (ZONE STATUS)""[OUTDOOR TEMPE

Página 104

The following menu choices are available:1=CONTROL 2=SECURITY3=BUTTON 4=ALL ↓5=TEMP 6=STATUS7=EVENTS 8=SETUP ↑Menu 1 - Selects C

Página 105

When a Two-Way Audio Module is being used:To talk or listen to the premises, press the 3 key."PLEASE CHOOSE: 2 TALK, 8 LISTEN, *: CANCEL."

Página 106

canceled. The Omni will say "CANCEL" when this happens. If youwish to cancel the emergency alarm before you have activated it, pressany ot

Página 107

Digital communications to a central station are generally superior tovoice communications to friends and neighbors for three reasons:- there is always

Página 108 - Set Up Names

case in your area, you must use a monitoring service if you want thepolice notified when your alarm is activated.As a preventative measure against pho

Página 109 - Set Up Voice

When an alarm is activated, the Omni will wait the Outside SirenDelay plus the Dial Out Delay. If your system is monitored by acentral station, it wi

Página 110 - Set Up Address

At any time during the message you can enter the Master or Managercode, simply by pressing the digits on the keypad of a Touch Tonephone. The Omni wi

Página 111

SETUPThe Setup menu is used to configure operating parameters, programyour system to do its automated control and security functions, andgive descript

Página 112 - SAMPLE PROGRAMS

Remember the code number. It will not be redisplayed.CODE X:0000-9999 0000=DISABLEPress the (↓ ) key. You will then be prompted for an authority l

Página 113

5:00 PM MTWTF-- #=CHNG×The times and days are changed by pressing the ' # ' key. Choose the 1 (TIME) key to change the On or Off times. Y

Página 114

entered time should be 13:00-23:59. Each item defaults to its currentvalue. TIME: HHMM ↑=AM ↓=PM DAYLIGHT SAVINGS TIME?0=NO 1=YESENTER DATE:MMDDYYD

Página 115 - Button Programs

To silence the beeper, press the ' * ' key.For more information, see Trouble Indications.When you have successfully completed a function, su

Página 116

automation in an Omni system. Each program must specify when thatprogram should execute and an action to be taken. The program mayalso specify a con

Página 117 - REQUIREMENTS

Menu 4 - Programs for All On/Off functionsMenu 5 - Programs for a particular Temperature zoneMenu # - Displays every programSelecting the 1 (CTRL) or

Página 118 - PLANNING

The first program is displayed once the down arrow is pressed. Thetop line displays the time or button/event that activates the programand any condit

Página 119 - COMMISSION (FCC) NOTICE:

Select 1 (YES) to delete all automation control programs in thesystem. Select 0 (NO) or press the ' * ' key to return to the Set UpProgram

Página 120

The Edit Program menu is used to specify each part of an automationprogram.EDIT PROGRAM1=WHEN 2=CMD 3=&COND- Selecting 1 (WHEN) allows the time

Página 121 -

Select 1 (TIME) to enter the new time. If the desired time is the time in which sunrise or sunset will occur,press the up arrow key for sunrise, or t

Página 122

To change days, press the down arrow (DAY) key. You will beprompted to enter the day(s) that the program will be activated. Press1-7 for Monday - Su

Página 123 - DIAL OUT PLANNER

Pressing the 1 (CTRL) key allows you to select the button for a controlunit activated event. You are first prompted to enter the desired unitnumber:U

Página 124

When you specify that the button is activated at the start of the delayby pressing the 1 (START EXIT) key, the mode is prefixed by "A-" for

Página 125 - INSTRUCTIONS TO CALLED PARTY

Pressing the 3 (ZONE) key allows you to select the button for asecurity zone activation event. You are first prompted to enter thedesired zone number

Página 126 - OMNI DEFAULT SETTINGS

SECURITY SYSTEM OPERATIONBefore going any further, you should know how to disarm yoursecurity system in the event that the alarm sounds. Turning the

Página 127

ANY ALARMBURGLARY ALARMFIRE ALARMGAS ALARMAUXILIARY ALARMFREEZE ALARMWATER ALARMDURESS ALARMTEMPERATURE ALARMPress the ' # ' key when the de

Página 128 - Set-Up Miscellaneous

Pressing the 7 (MISC) key allows you to select a button from a list ofother buttons. You are first prompted to select the button:SELECT BUTTON:WHEN P

Página 129

Press the 2 (SECURITY) key to arm and disarm the security system,or to bypass and restore an individual zone. The following menu isdisplayed:0=OFF

Página 130 - OMNI SPECIFICATIONS

Selecting the 3 (&COND) key, from the Edit Program menu, allowsthe condition for the program to be specified. This condition must betrue when the

Página 131

Next, select whether the system is considered in the specified modeduring the exit delay:INCLUDE EXIT DELAY?0=NO 1=YESIf area arming is being used, th

Página 132 - TABLE 1 - CHARACTER CODES

Select the # (OTHER) key to select a condition from a list of otherconditions. SELECT CONDITION:NONE ↓Choose "NONE" when e

Página 133 - TABLE 2 - VOICE DESCRIPTIONS

(shown as a "T" on the display). Press the NIGHT key to enter a ' # 'into the number. Enter a single ' - ' for no numb

Página 134

If Remote Commands Ok is set to No, then lights, appliances, and thesecurity system cannot be controlled from a remote telephone that dialsinto your h

Página 135

To enter phone numbers, press the keypad keys 0 - 9. You can put in adash (-) for legibility by pressing the OFF key. Press the ' # ' key af

Página 136

Press # to change the On and Off times - See Set Up Codes.DIAL OUT 1 ON:12:00 AM MTWTFSS #=CHNG×DIAL OUT 1 OFF:NEVER #=CHNG×For example, if

Comentários a estes Manuais

Sem comentários